Avon Inhibiting and Storage Procedure

 Inhibiting Procedure

The inhibiting procedure must only be carried out following a crank soak wash.

» Avon Crank Soak Wash Procedure


In off-shore installations it is advised that if the gas generator is to remain non-operational for a period
in excess of 3 hours the compressor must be inhibited for all other environments as detailed in the table below.

1]
Check inhibit ring exit holes are unrestricted.
2]
With the ignition and fuel supply off, initiate a starting cycle.
3]
Immediately the gas generator starts to rotate inject 3 pints (1,70 litres) of inhibiting fluid into the compressor.

Installed Gas Generator Storage Requirements

 ConditionsAnticipated Storage
Period
ABCDE
 Heated Building

 Dry Tropical
Up to 7 days    
8 - 30 days  
31 days - 6 months 
Over 6 months

 Unheated Building

 Temperate
Up to 7 days    
8 - 14 days  
15 - 30 days 
31 days - 6 months 
Over 6 months

 Humid Tropical
 (Above 80% humidity)
Up to 3 days    
4 - 8 days  
8 days - 3 months 
Over 3 months
  Key
A Fit covers and blanks
B Spray gas generator forward of combustion casing with temporary rust preventative
C Inhibit the compressor
D Insert Vapour Phase Inhibitor/Cyclohexylamine Carbonate Paper (VPI/CHC Paper)
E Bag gas generator and add desiccant
 
 